Description
This is a brand new 2.5 - 3 Ton's 208/230 Volt 1-Phase 28,000 BTU Direct Factory Replacement Copeland Compressor. The Model # is CR28K6E-PFV-875. Small piping changes may or may not be needed during installation. Thanks for looking and good luck!
Replaces Obsolete Bristol & Copeland Compressors
Air Conditioning & Heat Pump Compressor
Used in Equipment Models From: 2 1/2 to 3 Ton
Voltage @ 60 hz 208/230 Volts
Running Current @ BTUH 14.0 Amperes.
Discharge Inside Diameter 3/8 Inch.
Line Connection Suction Inside Diameter 3/4 Inch.
Base Mount Hole Center Size 7 1/2 x 7 1/2 Inches.
Length: 9 7/16 Inches.
Height: 14 3/16"
Width: 9 Inches
Refrigerant:R22.
Voltage:208/230.
Phase:1
Series:CR
Crank Case Heater:Yes
This compresser requires a run capacitor rated at 35 uf/MFD and 370 volt.Most condensing unit capacitors are dual capacitors, meaning they operate both thecompressor and the fan. To purchase the correct capacitor you will need toknow the uf rating on the fan motor as well as the compresser.
Start Capacitor rating is: 145-174 220Volt
Replaces Obsolete Bristol & Copeland Compressors
Air Conditioning & Heat Pump Compressor
Used in Equipment Models From: 2 1/2 to 3 Ton
Voltage @ 60 hz 208/230 Volts
Running Current @ BTUH 14.0 Amperes.
Discharge Inside Diameter 3/8 Inch.
Line Connection Suction Inside Diameter 3/4 Inch.
Base Mount Hole Center Size 7 1/2 x 7 1/2 Inches.
Length: 9 7/16 Inches.
Height: 14 3/16"
Width: 9 Inches
Refrigerant:R22.
Voltage:208/230.
Phase:1
Series:CR
Crank Case Heater:Yes
This compresser requires a run capacitor rated at 35 uf/MFD and 370 volt.Most condensing unit capacitors are dual capacitors, meaning they operate both thecompressor and the fan. To purchase the correct capacitor you will need toknow the uf rating on the fan motor as well as the compresser.
Start Capacitor rating is: 145-174 220Volt
To properly install a Compressor you need to have and use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. If the compressor is damaged due to improper installation procedures, the liability falls to the installer. All Sales are Final and there are no warranties!
Replaces:
Repair Difficulty Level
Partial list of Model numbers that use this part:
Use Ctrl+F and enter your model number for a quick search.