AC Condenser Compressor Replaces Ruud Rheem Weather King 55-23148-37, 55-23148-37S
- UPC:
- CMP63 639-U15
Description
This is a 4 / 5 Ton 208/220 Volts 1-Phase Direct Factory Replacement Copeland Scroll Compressor. the Copeland Model # is ZR54K5E-PFV-800, which replaces old Copeland Model #s ZR52K3-PFV-830, ZR52K3-PFV-930, ZR52K3-PFV-950. In some instances, small piping changes may be needed. It is rated at 53,500 BTU. Thanks for looking and good luck!
TECHNICAL SPECIFICATIONS
Capacity (BTU/HR): 53500
Type: Scroll
Refrigerant: R-22
Input Voltage (V): 208
Input Voltage (V): 230
No. of Phases: 1
Freq. (Hz.): 50
Freq. (Hz.): 60
Run Capacitor (uF/V): 80/370
Start Relay P/N: 42-25105-01
Start Capacitor (uF/V): 88-106/330
Start Capacitor Part Number: 43-17075-04
Rated Load Current (A): 28.2
Max. Continuous Current (A): 39.5
Locked Rotor Current (A): 146.0
Crankcase Heater Included?: No
Suction Line Location: 2
Suction Line Height (in.): 11-1/8
Suction Line Configuration: Stub Out
Suction Line Size (in.): 7/8
Discharge Line Location: 3
Discharge Line Height (in.): 15-3/8
Discharge Line Configuration: Stub Out
Discharge Line Size (in.): 1/2
Overall Compressor Height (in.): 16-7/16
Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2
To properly install a Compressor you need to have and use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. If the compressor is damaged due to improper installation procedures, the liability falls to the installer. All Sales are Final and there are no warranties!
TECHNICAL SPECIFICATIONS
Capacity (BTU/HR): 53500
Type: Scroll
Refrigerant: R-22
Input Voltage (V): 208
Input Voltage (V): 230
No. of Phases: 1
Freq. (Hz.): 50
Freq. (Hz.): 60
Run Capacitor (uF/V): 80/370
Start Relay P/N: 42-25105-01
Start Capacitor (uF/V): 88-106/330
Start Capacitor Part Number: 43-17075-04
Rated Load Current (A): 28.2
Max. Continuous Current (A): 39.5
Locked Rotor Current (A): 146.0
Crankcase Heater Included?: No
Suction Line Location: 2
Suction Line Height (in.): 11-1/8
Suction Line Configuration: Stub Out
Suction Line Size (in.): 7/8
Discharge Line Location: 3
Discharge Line Height (in.): 15-3/8
Discharge Line Configuration: Stub Out
Discharge Line Size (in.): 1/2
Overall Compressor Height (in.): 16-7/16
Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2
To properly install a Compressor you need to have and use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. If the compressor is damaged due to improper installation procedures, the liability falls to the installer. All Sales are Final and there are no warranties!
Replaces:
Repair Difficulty Level
Partial list of Model numbers that use this part:
Use Ctrl+F and enter your model number for a quick search.